Skip to main navigation Skip to search Skip to main content

The Sliding-Aperture Transform and Its Applicability to Deep-Level Transient Spectroscopy

  • Walter R. Buchwald
  • , Robert E. Peale
  • , Perry C. Grant
  • , Julie V. Logan
  • , Preston T. Webster
  • , Christian P. Morath
  • University of Central Florida
  • Air Force Research Laboratory
  • Massachusetts Institute of Technology

Research output: Contribution to journal › Article › peer-review

Abstract

A mathematical method is presented for the extraction of defect parameters from the multiexponential decays generated during deep-level transient spectroscopy experiments. Such transient phenomenon results from the ionization of charge trapped in defects located in the depletion width of a semiconductor diode. From digitized transients acquired at fixed temperatures, this method produces a rate–domain spectral signature associated with all defects in the semiconductor. For signal-to-noise ratio of 1000, defect levels with carrier emission rates differing by as little as 1.5 times may be distinguished.

Original languageEnglish
Article number5317
JournalApplied Sciences (Switzerland)
Volume12
Issue number11
DOIs
StatePublished - Jun 1 2022

ASJC Scopus Subject Areas

  • General Materials Science
  • Instrumentation
  • General Engineering
  • Process Chemistry and Technology
  • Computer Science Applications
  • Fluid Flow and Transfer Processes

Keywords

  • curve fitting
  • DLTS
  • emission rate
  • extraction
  • transient analysis

Fingerprint

Dive into the research topics of 'The Sliding-Aperture Transform and Its Applicability to Deep-Level Transient Spectroscopy'. Together they form a unique fingerprint.

Cite this